Opened
29 Nov 2022
due 06 Dec 2022 · Mei Tan
Stock from
PER-MAIN
Perth — main stores
Hours
8 h
0 timesheet entries
Request / fault
—
Findings & work done
Load cell zero drift 0.4 % — re-spanned. Function test OK.
Rental return inspection0 / 7
Serial & batch parts on RH55-001swap or upgrade — the unit BOM updates and the removed part goes to quarantine
| Item | Serial / batch | In sub-assembly | |
|---|---|---|---|
| 031-1601-R1-A RELEASE HOOK BODY — FORGED | 031-1601-S0004 | — | |
| 031-1610-R0-A RELEASE ACTUATOR & LATCH ASSEMBLY | 031-1610-S0004 | — | |
| 1000110 BATTERY MANAGEMENT SYSTEM BOARD 16S | BMS16-5058 | — | |
| 1000480 RADIO RECEIVER 2.4 GHz | HBC-R880297 | — | |
| 1000501 LiFePO4 PRISMATIC CELL 3.2 V 100 Ah | 1000501-B06 | — |
Timesheets
No hours booked yet.